- Rotate valve between the Pressure Pump and Cartridge Filter Housing to the “Off” Position
- Open the Drain Valve at the bottom of the Cartridge Filter Housing to drain the filter housing so the Pressure is Zero
-
- Note: DO NOT PROCEED TO THE NEXT STEP UNTIL NO WATER IS FLOWING OUT OF THE CARTRIDGE FILTER HOUSING – THERE SHOULD NOT BE ANY PRESSURE INSIDE OF THE CARTRIDGE FILTER HOUSING
- Remove the Filter Housing Clamp using a ½” Wrench
- Remove the ESD Reusable Cartridge Filter (ESD Part #: 4019)
- Clean the Cartridge Filter pleats with a garden hose
-
- Note: Do not use a pressure washer to clean – it will rip the polyester filter and will need to be replaced
- Clean the Cartridge Filter until all of the pleats have the material removed
- Re-install Cartridge Filter into Cartridge Filter Housing
- Re-install Cartridge Filter Lid and Clamp – tighten clamp
- Rotate valve between the Pressure Pump and Cartridge Filter Housing to the “On” Position
- Inspect Cartridge Filter Housing for leaks
- If additional assistance is needed contact ESD Waste2Water, Inc Service at 1-800-277-3279