The ESD Pressure Pump is regulated by a 30 – 50 PSI Pressure Switch to Turn On & Off the pump. At times the pressure switch needs to be adjusted. Steps to Pressure Switch Adjustments on a Pump Step 1: Using a 5/16” Wrench, remove the pressure switch cove SAFETY ALERT – do not… Read more »
Posts Categorized: DIY Videos
Regenerative Blower Replacement
Steps to Replace a Regenerative Blower Turn Blower Switch & Main electrical breaker is off Safety Alert: Turn Blower Switch & Main Electrical Breaker to the “Off” Position Remove Regenerative Blower Motor Cover Confirm Power is off with Multimeter Remove (4) Bolts & nuts from mounting plate Loosen and Remove 1 ½” PVC Connection Disconnect… Read more »
Air Compressor Maintenance – Replacing a Vane
Order Vane Replacement Kit from ESD Waste2Water, Inc – Part #’s: 3042 (Replacement Vanes), 3043 (Inlet Air Filter) & 3044 (Discharge Air Filter) How to Replace a Air Compressor: SAFETY FIRST: If Compressor is installed in ESD Waste2Water, Inc System – confirm Blower Switch is in the “Off” position and confirm electrical breaker in… Read more »
Weekly Microbe Inoculation of a Biological Wash Water System
Steps for Microbe Inoculation: Why inoculate a Biological System Weekly: The process of introducing a fresh batch of microbes on a weekly basis is to keep the microbial colony active inside of the Biological System. This also allows an Operator to check the system to confirm: A) The aeration is working B) The System has… Read more »
How to Properly Remove & Clean Cartridge Filter
Rotate valve between the Pressure Pump and Cartridge Filter Housing to the “Off” Position Open the Drain Valve at the bottom of the Cartridge Filter Housing to drain the filter housing so the Pressure is Zero Note: DO NOT PROCEED TO THE NEXT STEP UNTIL NO WATER IS FLOWING OUT OF THE CARTRIDGE FILTER HOUSING… Read more »